Analyzing Failures of Metal Components: Part Two

요약:

When studying a failure, great care must be used to avoid destroying important evidence. Detailed studies often require careful documentation of the service history (time, temperature, loadings and environment), supplemented by chemical analysis and electron micrographs. Further study of the sequence of events leading up to the failure, plus knowledge of the location, markings and condition of all adjacent parts after the incident, are necessary to confirm the analysis beyond reasonable doubt.
Of course, there is always the possibility of an unforeseen loading, unreported collision, or unanticipated vibration that may develop to cause premature failure. These factors may usually be diagnosed by careful examination and gathering of facts.

Analysis of failure

When studying a failure, great care must be used to avoid destroying important evidence. Detailed studies often require careful documentation of the service history (time, temperature, loadings and environment), supplemented by chemical analysis and electron micrographs. Further study of the sequence of events leading up to the failure, plus knowledge of the location, markings and condition of all adjacent parts after the incident, are necessary to confirm the analysis beyond reasonable doubt.

Of course, there is always the possibility of an unforeseen loading, unreported collision, or unanticipated vibration that may develop to cause premature failure. These factors may usually be diagnosed by careful examination and gathering of facts.

As supplementary information, we have appended a list of classifications as to cause of failure, and general guidelines to be following in determining the major cause or causes.

Initial Observations. Make a detailed study by visual inspection of the actual component that failed, preferably at the failure site as soon after the failure as possible. Profuse color photographs are essential to record every detail for later review.

Background Data. Gather all available data concerned with specifications and drawings, component design, fabrication, repairs, maintenance and service use. Concentration on obtaining facts pertinent to all possible failure modes is essential. Particular attention to environmental details, including normal service loads (as well as accidental overloads and cyclic loading) and resulting stress, temperature variations and gradients are desirable.

Supplementary Laboratory Studies. Make tests to verify that the material in the component actually possesses the specified composition, dimensions, processing and properties. Supplementary studies may be needed (for example, composition of corrosion products, simulated service or environmental tests, stress analysis, determination of microstructure and development of cracks, dynamic strain measurements, elevated or low temperature tests and surface replicas) to define the factors which contributed to the failure. Electron probe X-ray analysis can be useful in examining inclusions, microsegregation, or the composition of oxide or surface contaminants.

Frequently, examination of a fracture face with a low-power binocular microscope can reveal the type and cause of failure. However, the observer must be familiar with a wide variety of fracture textures, and be able to approach the examination without a preconceived idea of the cause for the fracture. Further confirmation can often be obtained by studies of cracks and structures at higher magnification, using small samples from the regions of failure.

Synthesis of Failure. List not only all positive facts and evidence, but also all the negative responses to the questions that may be asked about the failure. Sometimes it is important to know that specific things did not happen or certain evidence did not appear to determine what could have happened. From a tabulation of these data, the actual failure should be synthesized to include all available items of the evidence.

The cause will usually be classified in one of the categories outlined in the following list, and corrective action or applied research guidance can be recommended. Appropriate solutions may involve redesign, change of alloy and/or processing, quality control, protection against environment, changes in maintenance schedules, or restrictions on service loads or service life.

Classification of Failure Causes

Failures Due to Faulty Processing

  1. Flaws due to faulty composition (inclusions, embrittling impurities, wrong material).
  2. Defects originating in ingot making and casting (segregation, unsoundness, porosity, pipes, nonmetallic inclusions).
  3. Defects due to working (laps, seams, shatter cracks, hot-short splits, delamination, and excess local plastic deformation).
  4. Irregularities and mistakes due to machining, grinding, or stamping (gouges, burns, tearing, fins, cracks, embrittlement).
  5. Defects due to welding (porosity, undercuts, cracks, residual stress and lack of penetration, under bead cracking, heat affected zone).
  6. Abnormalities due to heat treating (overheating, burning, quench cracking, grain growth, excessive retained austenite, decarburization, precipitation).
  7. Flaws due to case hardening (intergranular carbides, soft core and wrong heat cycles).
  8. Defects due to surface treatments (cleaning, plating, coating, chemical diffusion, hydrogen embrittlement).
  9. Careless assembly (mismatch of mating parts, entrained dirt or abrasive, residual stress, gouges or injury to parts and the like).
  10. Parting line failures in forging due to poor transverse properties.

Failures due to Faulty Design Considerations or Misapplication of Material

  1. Ductile failure (excess deformation, elastic or plastic; tearing or shear fracture).
  2. Brittle fracture (from flaw or stress raiser of critical size).
  3. Fatigue failure (load cycling, strain cycling, thermal cycling, corrosion fatigue, rolling contact fatigue, fretting fatigue).
  4. High-temperature failure (creep, oxidation, local melting, warping).
  5. Static delayed fractures (hydrogen embrittlement, caustic embrittlement, environmentally stimulated slow growth of flaws).
  6. Excessively severe stress raisers inherent in the design.
  7. Inadequate stress analysis, or impossibility of a rational stress calculation in a complex part.
  8. Mistake in designing on basis of static tensile properties, instead of the significant material properties that measure the resistance of the material to each possible failure mode.

Failure Due to Deterioration During Service- Conditions

  1. Overload or unforeseen loading conditions.
  2. Wear (erosion, galling, seizing, gouging, cavitations).
  3. Corrosion (including chemical attack, stress corrosion, corrosion fatigue), dezincification, graphitization of cast iron, contamination by atmosphere.
  4. Inadequate or misdirected maintenance or improper repair (welding, grinding, punching holes, cold straightening, and so forth).
  5. Disintegration due to chemical attack or attack by liquid metals or platings at elevated temperatures.
  6. Radiation damage (sometimes must decontaminate for examination which may destroy vital evidence of cause of failure), varies with time, temperature, environment and dosage.
  7. Accidental conditions (abnormal operating temperatures, severe vibration, sonic vibrations, impact or unforeseen collisions, ablation, thermal shock and so forth).

기술 자료 검색

검색할 어구를 입력하십시오:

검색 범위

본문
키워드

머릿글
요약

이 문서는 전체 문서 중 일부분입니다. 이 주제에 대해 더 읽고 싶으시면 아래 링크를 클릭하시면 됩니다.

Total Materia Extended Range는 수천개 금속 합금의 열처리 조건 및 하중 조건에 대한 파괴 공학 변수 데이터베이스를 포함하고 있습니다. K1C, KC, 균열 성장 및 Paris 법칙 변수와 이에 대응되는 균열 성장 그래프가 제공됩니다.

단조 특성도 참조를 위해 추가되어 있으며 단조 특성을 통해 예상되는 빠진 변수의 추정치도 필요한 곳에는 포함되어 있습니다.

신속 검색에 검색할 재질명을 입력합니다. 원하신다면 국가/규격을 지정하신 후 검색 버튼을 클릭합니다.


결과 리스트에서 재질을 선택하시면, 일련의 규격 사양 소그룹이 나타납니다.


Total Materia 파괴 공학 데이터는 규격 사양서와 무관하므로, 어떠한 소그룹 내의 링크를 클릭하셔도 파괴 공학 데이터를 검토하실 수 있습니다.

데이터는 표로 출력되며, 가능한 곳에는 Paris 곡선(Region II)와 함께 출력되어 있습니다. 데이터 출처에 관한 정확한 참조가 각 데이터에 주어져 있습니다.


Total Materia 데이터베이스를 사용해 보실 수 있는 기회가 있습니다. 저희는 Total Materia 무료 체험을 통해 150,000명 이상의 사용자가 이용하고 있는 커뮤니티로 귀하를 초대합니다.