Mechanical Properties


Temperature

0 - 30°C
30 - 100°C
100 - 300°C
≥ 300°C
PROPERTY / VALUE
Yield Strength, Rp0.2 250 MPa view details
Yield Strength, Rp0.2 val1
Full data access requires a free trial. Sign Up Free
MPa
view details
Yield Strength, Rp0.2 val1
Full data access requires a free trial. Sign Up Free
MPa
view details
Yield Strength, Rp0.2 val1
Full data access requires a free trial. Sign Up Free
MPa
view details
Tensile Strength 450 — 630 MPa view details
Elongation, A 17 % view details
Impact Energy val1
Full data access requires a free trial. Sign Up Free
J
view details
Yield Strength, Rp0.2 36.3 ksi view details
Yield Strength, Rp0.2 val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Yield Strength, Rp0.2 val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Yield Strength, Rp0.2 val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Tensile Strength 65.3 — 91.4 ksi view details
Elongation, A 17 % view details
Impact Energy val1
Full data access requires a free trial. Sign Up Free
ft·lb
view details

Physical Properties


Temperature

≤ 0°C
0 - 30°C
30 - 100°C
100 - 300°C
≥ 300°C
PROPERTY / VALUE
Modulus of Elasticity 190 — 210 GPa view details
Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
GPa
view details
Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
GPa
view details
Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
GPa
view details
Shear Modulus val1
Full data access requires a free trial. Sign Up Free
GPa
view details
Shear Modulus val1
Full data access requires a free trial. Sign Up Free
GPa
view details
Shear Modulus val1
Full data access requires a free trial. Sign Up Free
GPa
view details
Shear Modulus val1
Full data access requires a free trial. Sign Up Free
GPa
view details
Dynamic Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
GPa
view details
Dynamic Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
GPa
view details
Dynamic Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
GPa
view details
Dynamic Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
GPa
view details
Dynamic Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
GPa
view details
Density val1
Full data access requires a free trial. Sign Up Free
kg/dm³
view details
Poisson Coefficient val1
Full data access requires a free trial. Sign Up Free
view details
Coefficient of Thermal Expansion (CTE) val1
Full data access requires a free trial. Sign Up Free
10-6/°C
view details
Coefficient of Thermal Expansion (CTE) val1
Full data access requires a free trial. Sign Up Free
10-6/°C
view details
Coefficient of Thermal Expansion (CTE) val1
Full data access requires a free trial. Sign Up Free
10-6/°C
view details
Coefficient of Thermal Expansion (CTE) val1
Full data access requires a free trial. Sign Up Free
10-6/°C
view details
Coefficient of Thermal Expansion (CTE) val1
Full data access requires a free trial. Sign Up Free
10-6/°C
view details
Thermal Conductivity 33 — 50 W/(m∙°C) view details
Thermal Conductivity val1
Full data access requires a free trial. Sign Up Free
W/(m∙°C)
view details
Thermal Conductivity val1
Full data access requires a free trial. Sign Up Free
W/(m∙°C)
view details
Thermal Conductivity val1
Full data access requires a free trial. Sign Up Free
W/(m∙°C)
view details
Heat Capacity val1
Full data access requires a free trial. Sign Up Free
J/(kg∙°C)
view details
Heat Capacity val1
Full data access requires a free trial. Sign Up Free
J/(kg∙°C)
view details
Heat Capacity val1
Full data access requires a free trial. Sign Up Free
J/(kg∙°C)
view details
Heat Capacity val1
Full data access requires a free trial. Sign Up Free
J/(kg∙°C)
view details
Heat Capacity val1
Full data access requires a free trial. Sign Up Free
J/(kg∙°C)
view details
Electrical Resistivity 0.18 — 0.298 Ω∙mm²/m view details
Electrical Resistivity val1
Full data access requires a free trial. Sign Up Free
Ω∙mm²/m
view details
Electrical Resistivity val1
Full data access requires a free trial. Sign Up Free
Ω∙mm²/m
view details
Electrical Resistivity val1
Full data access requires a free trial. Sign Up Free
Ω∙mm²/m
view details
Electrical Conductivity val1
Full data access requires a free trial. Sign Up Free
S/m
view details
Electrical Conductivity val1
Full data access requires a free trial. Sign Up Free
S/m
view details
Electrical Conductivity val1
Full data access requires a free trial. Sign Up Free
S/m
view details
Electrical Conductivity val1
Full data access requires a free trial. Sign Up Free
S/m
view details
Modulus of Elasticity 27.6 E+03 — 30.5 E+03 ksi view details
Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Shear Modulus val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Shear Modulus val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Shear Modulus val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Shear Modulus val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Dynamic Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Dynamic Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Dynamic Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Dynamic Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Dynamic Modulus of Elasticity val1
Full data access requires a free trial. Sign Up Free
ksi
view details
Density val1
Full data access requires a free trial. Sign Up Free
lb/in³
view details
Poisson Coefficient val1
Full data access requires a free trial. Sign Up Free
view details
Coefficient of Thermal Expansion (CTE) val1
Full data access requires a free trial. Sign Up Free
10-6/°F
view details
Coefficient of Thermal Expansion (CTE) val1
Full data access requires a free trial. Sign Up Free
10-6/°F
view details
Coefficient of Thermal Expansion (CTE) val1
Full data access requires a free trial. Sign Up Free
10-6/°F
view details
Coefficient of Thermal Expansion (CTE) val1
Full data access requires a free trial. Sign Up Free
10-6/°F
view details
Coefficient of Thermal Expansion (CTE) val1
Full data access requires a free trial. Sign Up Free
10-6/°F
view details
Thermal Conductivity 19.1 — 28.9 BTU/(h∙ft∙°F) view details
Thermal Conductivity val1
Full data access requires a free trial. Sign Up Free
BTU/(h∙ft∙°F)
view details
Thermal Conductivity val1
Full data access requires a free trial. Sign Up Free
BTU/(h∙ft∙°F)
view details
Thermal Conductivity val1
Full data access requires a free trial. Sign Up Free
BTU/(h∙ft∙°F)
view details
Heat Capacity val1
Full data access requires a free trial. Sign Up Free
BTU/(lb∙°F)
view details
Heat Capacity val1
Full data access requires a free trial. Sign Up Free
BTU/(lb∙°F)
view details
Heat Capacity val1
Full data access requires a free trial. Sign Up Free
BTU/(lb∙°F)
view details
Heat Capacity val1
Full data access requires a free trial. Sign Up Free
BTU/(lb∙°F)
view details
Heat Capacity val1
Full data access requires a free trial. Sign Up Free
BTU/(lb∙°F)
view details
Electrical Resistivity 299 E-06 — 495 E-06 Ω∙circular·mil/ft view details
Electrical Resistivity val1
Full data access requires a free trial. Sign Up Free
Ω∙circular·mil/ft
view details
Electrical Resistivity val1
Full data access requires a free trial. Sign Up Free
Ω∙circular·mil/ft
view details
Electrical Resistivity val1
Full data access requires a free trial. Sign Up Free
Ω∙circular·mil/ft
view details
Electrical Conductivity val1
Full data access requires a free trial. Sign Up Free
S/in
view details
Electrical Conductivity val1
Full data access requires a free trial. Sign Up Free
S/in
view details
Electrical Conductivity val1
Full data access requires a free trial. Sign Up Free
S/in
view details
Electrical Conductivity val1
Full data access requires a free trial. Sign Up Free
S/in
view details

Composition

CRITERIA
VALUE
UNIT
CAS NUMBER
CRITERIA
Al
VALUE
Al total; Shall be determined and given in the inspection document.
UNIT
%
CAS NUMBER
7429-90-5
CRITERIA
C
VALUE
0.08 – 0.14
UNIT
%
CAS NUMBER
7440-44-0
CRITERIA
Cr
VALUE
2.00 – 2.50
UNIT
%
CAS NUMBER
7440-47-3
CRITERIA
Cu
VALUE
val1
Full data access requires a free trial. Sign Up Free
UNIT
%
CAS NUMBER
7440-50-8
CRITERIA
Cu+6Sn
VALUE
val1
Full data access requires a free trial. Sign Up Free
UNIT
%
CAS NUMBER
CRITERIA
Mn
VALUE
val1
Full data access requires a free trial. Sign Up Free
UNIT
%
CAS NUMBER
7439-96-5
CRITERIA
Mo
VALUE
val1
Full data access requires a free trial. Sign Up Free
UNIT
%
CAS NUMBER
7439-98-7
CRITERIA
N
VALUE
val1
Full data access requires a free trial. Sign Up Free
UNIT
%
CAS NUMBER
7727-37-9; 17778-88-0
CRITERIA
P
VALUE
val1
Full data access requires a free trial. Sign Up Free
UNIT
%
CAS NUMBER
7723-14-0
CRITERIA
S
VALUE
val1
Full data access requires a free trial. Sign Up Free
UNIT
%
CAS NUMBER
7704-34-9
CRITERIA
Si
VALUE
val1
Full data access requires a free trial. Sign Up Free
UNIT
%
CAS NUMBER
7440-21-3

EN 10028-2: 2017 / Flat products made of steels for pressure purposes - Part 2: Non-alloy and alloy steels with specified elevated temperature properties

Heat Treatments

  • Austenitized: 920 - 980°C; Tempered: 650 - 750°C.
  • Normalizing and tempering (+NT): 900-960°C, air cooling. Tempering: 680-750°C, air cooling. Normalizing includes Normalizing Forming, Normalized Forming shall be carried out in a temperature range from 880-1000°C.<br />It may be necessary in the case of wall thickness T above 10 mm or T/D > 0.15 to apply quenching and tempering in order to achieve the intended structure and material properties.